Daily drop in FC. 2–4 ppm is typical outdoors.
From the manual: lb of chlorine per 24 h.
Cell too small for this runtime
100% and longer runtime
At 100% the cell needs about 8.6 hours of pump time a day to replace 3 ppm. Run the pump longer than 8 hours.
- Chlorine used per day
- 0.5 lb
- Cell output in 8 h at 100%
- 0.47 lb
- Pump hours needed at 100%
- 8.6 h
- FC added per hour at 100%
- 0.35 ppm
Check FC daily for a week after any change and adjust in steps of 5–10%.
- Never mix pool chemicals with each other, wet or dry.
- Always add chemicals to water, never water to chemicals.
- Follow the manufacturer's label. It overrides any calculator, including this one.
How it's calculated
A salt cell only makes chlorine while water flows through it, so its daily production depends on its rating and on how long the pump runs. The setting is the share of that production your pool actually needs.
Worked example
A 20,000 gallon pool uses 3 ppm of chlorine a day. The cell is rated at 1.4 lb a day and the pump runs 8 hours:
- Chlorine used: 3 × 75,708 L = 227,125 mg = 0.501 lb a day.
- Production at 100% in 8 hours: 1.4 × 8 ÷ 24 = 0.47 lb.
- Setting: 0.501 ÷ 0.47 = 107%. That is over 100%, so the pump must run about 8.6 hours at 100%, or longer at a lower setting.
- Skimmer & main drainpull water and floating debris out of the pool
- Pumpbasket catches leaves; impeller moves the water
- Filtertraps fine particles; pressure gauge shows when to clean
- Heater / heat pumpoptional; needs minimum flow to switch on
- Chlorinator / salt cellalways last, so strong chlorine never passes the heater
- Return jetspush clean water back and mix the pool
Setting for a 1.4 lb/day cell with 8 pump hours
| Pool size | 2 ppm/day | 3 ppm/day | 4 ppm/day |
|---|---|---|---|
| 10,000 gal | 36% | 54% | 72% |
| 15,000 gal | 54% | 80% | over 100% |
| 20,000 gal | 72% | over 100% | over 100% |
| 25,000 gal | 89% | over 100% | over 100% |
| 30,000 gal | over 100% | over 100% | over 100% |
Common mistakes
- Setting 100% and forgetting it. Chlorine builds up on cloudy days and runs short on sunny ones. Check FC and adjust.
- Low CYA. Without 60–80 ppm of stabilizer, the sun destroys chlorine as fast as the cell makes it.
- Low salt. Below the range in the manual, output drops and the cell wears faster. Use the salt calculator.
- A scaled cell. White crust on the plates cuts output. Inspect it every few months; see saltwater pool maintenance.
- Using the cell to shock. Most cells cannot raise chlorine to shock level quickly. Use liquid chlorine and the shock calculator.
Frequently asked questions
How do I find out how much chlorine my pool uses per day?
Test free chlorine at the same time two days in a row without adding any and with the cell off; the drop is your daily use. Sunny outdoor pools with CYA in range typically lose 2–4 ppm a day, less with a cover or shade.
Where do I find my cell rating?
In the manual or on the manufacturer's spec sheet, usually as "pounds of chlorine per 24 hours" or "gallons per day of equivalent liquid chlorine". Cells sold for a given pool size are often rated for a larger pool than is comfortable to run at.
Is it better to run the pump longer at a lower percentage?
Both deliver the same chlorine. Longer runtime at a lower setting spreads production through the day and keeps FC steadier, but costs more pump electricity. With a variable-speed pump, long low-speed runs are usually the cheapest option.
Why does my salt cell need more output in summer?
Sunlight, heat and swimmers all use chlorine faster. Expect to raise the setting or the pump hours in the hottest months and lower them in spring and autumn.
Does a higher setting wear the cell out faster?
Cell life depends on total hours of production. Running at 100% for fewer hours or 50% for more hours wears it about the same. Keeping salt and CYA in range and the cell clean matters more.
Related calculators
See all Pool Water Chemistry Calculators · Pool FAQ.
Sources and further reading
- Trouble Free Pool. Pool School (free chlorine to CYA relationship and the SLAM shock method)
- Pool & Hot Tub Alliance (PHTA). ANSI/APSP/ICC-5 American National Standard for Residential Inground Swimming Pools (residential water-quality ranges and filter design rates)
- U.S. Centers for Disease Control and Prevention (CDC). Home Pool and Hot Tub Water Treatment and Testing
- National Library of Medicine, PubChem. Sodium hypochlorite (liquid chlorine)
Figures are cross-checked against these sources and against hands-on results. External links open in a new tab; SmartPoolCalc is not affiliated with any of them.